Thank you for purchasing Elekon AG’s Microphone Tester Pulse.

The Microphone Tester  Pulse is   an  ultrasonic   microphone  test  device.  It   emits  ultrasonic   test

pulses   that   can   be   to   used   check   the   functioning   of   your   bat   detector.   There   are   two   test

sequences to check different device types – BATLOGGER and BATSCANNER. 

The   device   is   intended   for   usage   with   Elekons   BATLOGGER   and   BATSCANNER   devices,

however, it may function with other bat detectors and ultrasonic devices as well.

It is the ideal test device to have always with you for a quick check ahead of your bat walk.





Notes

Instructions for safe use:

Please read this manual carefully and entirely before using this product. The product

must be properly installed before usage.

Warning:

The   device   must   be   protected   from   rain   and   generally   from   liquids   and   any

environmental influences. 

Battery:

Only use standard CR2032 button cell batteries. Follow the instructions in chapter  6

to change the battery.

Repairs should only be carried out by a qualified customer care centre. 



Frequency-response:

Due to the small size and therefore limited power of the device it is not possible to

output a flat frequency-response curve. The device is intended to quickly check the

general functionality of a bat detector, not to perform detailed measurements or even

calibrations.



Package Contents

Microphone Tester Pulse (incl. CR2032 button cell battery)



This manual





Features

Emits ultrasonic test pulses 



Bat detector mode

Bat recorder mode



Status indication LED





General usage

1. Go to a quiet place for best results.

2. Place the device with the speaker opening directly on top of the ultrasonic microphone to

test.


3. Press the ‘BATLOGGER’ or ‘BATSCANNER’ button according to the device to test (see

below).


4. The Status LED indicates the ultrasonic output 

5. Check if the test pulses are recorded or transformed into audible range as expected (see

below).



Test modes

The device features two test modes with different pulse sequences.



5.1 

BATLOGGER mode

   


 

This   mode   is   intended   for   ultrasonic   recording   devices   such   as   a   BATLOGGER   M.  A  short



sequence (ca. 380 ms) of ultrasonic pulses is output. The BATLOGGER records this sequence to

the SD card. To check the correct functioning of the BATLOGGER, this recording can be analysed

on a computer.

1. Place the device with the speaker opening directly on top of the ultrasonic microphone

(see illustrations above).

2. Press the ‘BATLOGGER’ button to start the sequence. The LED flashes red.

3. The BATLOGGER should trigger a new recording automatically (with default settings). If a

BATLOGGER device with live monitoring function is used, a short beep should be heard

on the headphones/speaker. 

4. When the sequence is done, the LED turns off and the recording is stored onto the SD

card.

5. Place   the   SD   card   into   a   computer,   open   the   recording   file   (WAV)   with   an   audio



application  (e.g. Audacity  ®)  and analyse  the  recording.  Check   if all the pulses  were

recorded properly. A spectrogram should look like this:

One pulse at approx. 45 kHz for 20 ms to trigger the recording

Each one pulse at approx. 20, 30, 40, 50, 60, 70, 80, 90, 100 kHz for 20 ms to test the frequency

response.

5.2 

BATSCANNER mode

                

This   mode   is   intended   for   bat   detector   devices   such   as   a   BATSCANNER   or   BATSCANNER



STEREO. Nine short ultrasonic pulses with varying frequencies and 500 ms duration are output.

The BATSCANNER triggers to these pulses and transforms them into audible range.

1. Place the device with the speaker opening directly on top of the ultrasonic microphone

(see illustrations above).

2. Press the ‘BATSCANNER’ button to start the sequence.

3. The first ultrasonic pulse (20 kHz, 500 ms) is output and the LED flashes red.

4. The BATSCANNER should trigger to approx. 20 kHz and a beep should be heard on the

headphones/speaker.

5. For each frequency (20, 30, 40, 50, 60, 70, 80, 90, 100 kHz) a pulse is output in the same

way.


6. The BATSCANNER should trigger to each frequency (approx.) and beep.



Troubleshooting

LED does not light up when a button is pressed:



Check/replace battery

Device under test does not trigger to the pulses:



Check trigger settings, use default settings

Microphone may be defective, check microphone with higher-grade test equipment



Not all pulses trigger correctly:

Check placement of the device to the microphone



Repeat test in a quiet environment

Microphone   sensitivity   may   be  affected,   check   microphone   with  higher-grade   test



equipment

Replace battery:



1.

Use a flat-head screwdriver on the gap on the left side of the housing to 

carefully open it.

2.

Replace the CR2032 button cell battery.



3.

Place circuit board back into the cap and close the housing by pushing the cap 

onto the base until you hear a “click”.



Specifications

Dimensions L×W×H, Weight

60×40×19 mm, 25 g

Weather protection

IP40

Power supply



1× CR2032 button cell battery

Operating environment

0°C to 40°C, < 80% RH

Display


LED

Speaker


Piezo, max. 33dB at 10cm / 20kHz, Range: 20 – 100 kHz (-30dB)



Disclaimer

Unauthorized reproduction of this manual is prohibited.



Changes to the information as well as technical specifications and design of the product

reserved.

The illustrations used in this manual may differ from the actual product.



Notwithstanding the foregoing Elekon AG can not be held liable for losses, arising from

the use of this product.

www.batlogger.com

©  2016  Elekon  AG,  All  rights  reserved.  Elekon,  the  Elekon  logo, 

BATLOGGER and BATSCANNER are trademarks and / or registered 

trademarks  of  Elekon  AG.  Other  brand  and  product  names  are 

trademarks  or  registered  trademarks  of  their  respective  owners. 

Information may be changed without prior notice.

Elekon AG

Cheerstrasse 16

CH-6014 Luzern

www.batlogger.com

Made in Switzerland

May 2016

Manual

Elekon AG

Cheerstrasse 16

CH-6014 Luzern



Microphone Tester 

Pulse

en

Document Outline



Yüklə 277,62 Kb.

Dostları ilə paylaş:




Verilənlər bazası müəlliflik hüququ ilə müdafiə olunur ©www.azkurs.org 2020
rəhbərliyinə müraciət

    Ana səhifə